| Suite
Phones |
|
| Annunciator
Panels |
|
| Transformers
& Power Supplies |
|
| Emergency
Switch Stations |
|
PACIFIC
ELECTRONICS TRANSFORMER & POWER SUPPLIES
FORMERLY AUTH-FLORENCE |
|
UM598TM
Function: Provides 16 VAC to amplifier for
system operation and allows use of 24 VAC door release
Size: 2 ½”H x 2 1/8”W
x 2 ½”D
Mounting: Has knockouts for mounting to standard
outlet box. Only low voltage terminals are exposed.
Primary: 110 volts, 60 HZ. Secondary:
16/24 VAC. 30 VA |
|
T50F
Function: Provides
24 VAC for system operation
Size:3 ½”H x 5 5/8”W
x 4”D
Mounting: Has knockouts for mounting to standard
outlet box.
Primary: 110 volts, 60 HZ.
Secondary: 24 VAC. 50 VA |
|
T100F
Function:
Provides 24 VAC for system operation
Size:3 ½”H x 5 5/8”W
x 4”D
Mounting: Has knockouts for mounting to
standard outlet box.
Primary: 110 volts, 60 HZ.
Secondary: 24 VAC. 100 VA
|
|
PS17
Function: Provides DC power required for
systems
(Solid State).
Primary :118 VAC, 60 Hz
Secondary: 24 VDC, 4 AMP.
Mounting: Surface type
Enclosure: Hinged steel cabinet 9”
wide, 10” high, 4 1/2” deep. |
|
PS27A
Function: Provides DC power required for
various systems (Solid State).
Primary :118 VAC, 60 Hz
Secondary: 24 VDC, 4 A total from all output
terminals. Continuous DC(2.0 a max.) or pulsed DC (2.0 a max)
2 System Annunciator Outputs:
There are two outputs (one steady and one pulsed) available
whenever current draw is sensed by the power supply.
Use outputs in conjunction with a remote sounder.
Protection: Circuit breaker . 4 amp.
Mounting: Surface type
.
Enclosure : Steel cabinet with hinged cover;
9” wide, 10” high, 4 1/2” deep, suitable
for wall or surface mounting.
Wiring: Input wires are: skinned for wire
nut connection. Output terminations are barrier strip screw
terminals. |
| |
COMPANY
| ELECTRONIC PRODUCTS | INTERCOM
PRODUCTS
NURSE & E-CALL PRODUCTS | CUSTOMER
LIST | CONTACT US
© 2005-2011 Pacific Electronics