FORMERLY AUTH-FLORENCE
 
Pacific 730 Series Door Security Annunciator provides immediate visual and audible indication of unauthorized entry/exit from any given number of locations.
FEATURES:
• Distinct Call Identification
•Constant Audible Indication
•Lo-Glo Supervised Mode
• Hi-Glo Alarm Mode
•Flush, Surface Mounting
Door Security Annunciator shall consist of
the following components:
A: One lamp indicator for each location being monitored. Lamp shall be sub-miniature, Bi-Pin M-23, GE7387 or equal replaceable from the front with an average life expectancy of 50,000 hours.
B: A Pacific Buzzer, Catalog No. 07954605 shall be provided to generate a constant audible indication upon opening of a supervised door. Constructed of molded plastic the dust proof, tamper proof buzzer shall have standard screw type connecting terminals with an adjustment setting.
C: Screw type terminals shall be provided for system’s wiring termination.
D: Numerical room designation sheets shall be provided with each Door Security Annunciator. Application to a protective mylar plastic strip shall be accomplished without the use of special tools.
E: Faceplate shall be of extruded aluminum with a satin, natural anodized finish.

Catalog number & Dimensions:
Flush Mount Panels
92144100
Annunciator panel w/ buzzer, 12 lamp capacity
92144200 Annunciator panel w/ buzzer, 24 lamp capacity
Surface Mount Panels
92124100
Annunciator panel w/buzzer, 12 lamp capacity
92124200 Annunciator panel w/ buzzer 24 lamp capacity
 
PS17 Features:
•Reliable Continuous Operation
•Compact Design
•Flush or Surface Mounting
Function: Provides DC power required for systems (Solid State).
Primary :118 VAC, 60 Hz
Secondary: 24 VDC, 4 AMP.
Mounting: Surface type
Enclosure: Hinged steel cabinet 9” wide, 10” high, 4 1/2” deep.
 
Features:
•Key-Switch Operation
•Single Gang Mounting
Function:
The 730 Door Control Module is required at each location to be monitored. Key switch operated, the door control module places a monitored location into a supervised or unsupervised mode. In the supervised mode, through the operation of the key switch unit can reset all signals at the Door Security Annunciator upon activation of an alarm.
Door Control Module Specifications:
1. Door control module shall permit door locations to be placed under or removed from supervision. If required two or more doors may be wired to be controlled from one door control mode.
2. Key switch operated, all door control modules shall be keyed alike with key removal either in the unsupervised or supervised mode.
3. Audible signal shall be silenced and lamp restored to normal
LO -GLO mode either by momentarily operating key at the door control module or by momentarily pressing the illuminated lamp/button on the Annunciator Panel once door is restored to the normally closed position.
4. Screw type terminals shall be provided for system wiring termination.
5. Door Control Module shall be mountable on a single gang electrical backbox.
Door Control Module:
Model #731, Catalog #926600-00
Annunciator: Model # 730, Catalog #92144100-12 lamp & #92144200- 24 lamp.
• Door Out of Supervision
— No light on annunciator for this door zone
• Door Being Supervised
— Dim light on annunciator for this door zone.
• Door under supervision and opened
— Bright light on annunciator for this door and an audible signal.
Resetting Calls:
Door alarm calls may be silenced by momentarily operating the key at the Door Control Module or by momentarily pressing the illuminated light on the main annunciator. The door being reset must be in the normal closed position. Door alarm calls being reset will restore the particular annunciator
light to a dim supervised level.
 
MODEL#92670000
FUNCTION: For tandem usage with the door control module Pacific catalog number 92660000, the magnetic door contact device is designed for surface mounting at the door or window.
Door Contact specifications: Magnetic door contact device shall be supplied in a dust free enclosure and be applicable to all surface mounting requirements. Door contact shall be single pole, normally open when the door is closed.
 

COMPANY | ELECTRONIC PRODUCTS | INTERCOM PRODUCTS